Firmware AB2xx, AB3xx, AB4xx, DA3xx, PF3xx

 

For this control boxes you have to take care during the update. If the memory stick is damaged or there is a power off during update the control box is empty!

In that case you have download software by IF232-USB cable and EfkaLoader software!

 

Update by usb memory stick (FAT/FAT16 format, smaller 4GB):

1.       copy and extract the file to an empty usb memory stick (direct on the root, no subfolder!)

2.       power off control box

3.       plug usb memory stick to control box

4.       enter parameter menu with code number (-link) and go to parameter .5.2.7.

5.       Press “E” key, you will see “hdl_”. Press “>>” key to see the file name. Select the correct file by pressing “+” and “-“ key. Press “E” key two times.

 

Control Box Type

Files

AB221A Y1-Y6 1)

5131L_14030407 -link

AB221A Y7,Y8,… 1)3)

5132C_18112608 -link

AB321A Y1-Y3 1)

5231L_14030407 -link

AB321A Y4,Y5,… 1) 3)

5232C_18112608 -link

AB425S 2)

5850S_18030809 -link

DA321G Y1-Y4 1)

5321V_15011916 -link

DA321G Y5,Y6,… 1) 3)

5325B_18091113 -link

PF321A

6012C_10101109 -link

1)You have to check the hardware version before you update the control box. When you update by usb memory stick you can only see the correct files because of file ending.

2)Sometimes after download new software you see “PROG” in the display. Please wait until message disappears. When ready you will see B3 (Update FAIL) or B4 (Update OK) message.

3) The hardware for AB221A, AB321A and DA321G changed:

5131 -> 5132

5231 -> 5232

5321 -> 5325

The processor is different. To activate 15V on B18 you have no jumper you have to change a parameter. There is no jumper anymore.

-ABxxxA control box parameter F362=1 to activate 15V on B18

-DAxxxG control box parameter F375=1 to activate 15V on B18

When you used an old hardware for your machine we recommend to test everything with the new hardware to ensure that everything works!

 