Error messages which are send by B18 communication
Common message: %F10001
%: NAK / not acknowledge
F1: adress of control box
0001 or 01: error number. Number is a hexadecimal value has a length of 2 or 4 numbers
Error numbers:
01  PARA_UNKNOWN, unknown parameter number
 02  PARA_ERR_MIN, parameter value is smaller than allowed
 03  PARA_ERR_MAX, parameter value is bigger than alowed
 04  VARIO_AKTIV, change of parameter value not allowed when programming/variocontrol active
 05  SEWING, change of parameter value not allowed when sew active
 06  UNKNOWN_COMMAND, unknown command
 07  DATA_MISSING, no data after '='-sign
 08  UNKNOWNHEADER, unknown header ex. 'P', 'T', 'H'
 09  TEST_NOT_ENABLED, communication not enabled
 0A  TEST_UNKNOWN_COMMAND_E, unknown sign after 'E'-sign for test command
 0B  GET_DATA_NOT_ALOWED, It is not possible to request data
 0C  SET_DATA_NOT_ALOWED, Setting data not allowed or not possible
 0D  CODE, wrong code
 0E  SEPARATOR_EQU, '='-sign is missing
 0F  SEPARATOR_SEMI, ';'-sign is missing
 10  TEACH_PROGNUM_NOTEXIST, Teachin-program number not exist
 11  TEACH_NAHTNUM_NOTEXIST, Teachin-sew number not exist
 12  PROGNUM_MISSING, Teachin: program number missing 
 13  NAHTNUM_MISSING, Teachin: sew number missing 
 14  IS_NOT_AN_FP, FP-Data was send to a non FP control
 15  ACESS_DENIEDED, access not allowed, wrong code number
 16  DESCRIPT_MISSING, 'X' or 'A'-sign missing
 17  PARA_NOT_IN_TEACHINLIST
 18  NOT_ENOUGH_SPACE     
 19  TEACH_DATA_NOTEXIST  
 1A  TO_MUCH_PARAMETER       
 1B  SLAVE_IS_BUSY         
 1C  ERRCSI_UNKNOWN_ELEM_SYSIO
 
            
             
            
             
            
             
            
             
            
            